Login

LocoDawn

Locomotive Diagrams, Analysis, Wiring & Navigation

3-Phase Locomotive Commissioning, Testing & Troubleshooting Platform

Wiring, testing & fault-finding of 3-phase locomotives — all in one place
Search any cable, tap its number on the circuit sheet, see what the Loco Display (DDU) shows, follow the test steps and trace the fault.
Cable IndexCircuit DiagramsLT / HT Testing Sequence TestPanelsFault Lookup
WAG-9 · WAP-7 · WAP-5
▸ Field-Trialled & User-Verified
PATENT APPLICATION NO. 202531019954 · TAP FOR TRIAL DETAILS
Patent Application No.: 202531019954 (AELSLIS Private Limited) — ipindia.gov.in
Field Trial: 16.04.2025 – 27.08.2025 at Dankuni Loco Works, CLW (referred to as ELAAU/CLW, Dankuni in trial-period documents).
44 propulsion & auxiliary system tests conducted — across ALSTOM, MEDHA, SIEMENS/ABB/CGL/BHEL propulsion systems, and auxiliary sub-systems (22 locomotives).
▸ View breakdown
Propulsion SystemLocos Tested
ALSTOM6
MEDHA6
SIEMENS / ABB / CGL / BHEL10
Auxiliary systems (all types)22
09.09.2025: 47 Supervisors & Technical Staff of the Testing Section, ELAAU/CLW Dankuni jointly requested permanent implementation based on this trial — a field-level, unsolicited endorsement.
Source: CLW/Dankuni/Testing/Modified Logic Box Final Trial Report dated 27.08.2025, and Joint Request dated 09.09.2025. Records available at Dankuni Loco Works, CLW/Dankuni (formerly ELAAU/CLW, Dankuni) and with AELSLIS Private Limited.
Cable Index
Circuits
LT Testing HT Testing
Panels
VCU
Testing & Troubleshooting
VCU I/O Signals
Fault Lookup
Search All
Abbreviations
Ask
Quiz
🔍 Type cable number or equipment to search
Search by cable number or equipment (e.g. "1218", "5673A", "BPCS", "XK22V")